Typical questions in claims handling
Is there hail damage although hardly any module shows visible breakage?
After a hailstorm over a 4.2 MWp ground-mounted plant in Middle Franconia, only 23 modules had broken glass. Electroluminescence on a sample of 1,200 modules found 847 cell cracks.
Cell cracks after hail in an electroluminescence assessment → · How electroluminescence testing works →
Did a DC arc cause the fire?
On a 180 kWp rooftop system in the Rhine-Main region, improperly crimped MC4 connectors caused a cable fire. The contact resistance at the point of damage was 2.8 Ω.
Fire caused by a DC arc on a commercial rooftop → · How DC arc faults develop →
Is a hotspot only a yield loss or also a fire risk?
On a 420 kWp commercial rooftop system, 87 modules exceeded 85 °C, the hottest reached 142 °C on the rear side. Causes were failed bypass diodes, cracked cells with short circuits and broken solder joints.
Hotspot assessment of a 420 kWp system →
Which gases are released when a storage cell goes into thermal runaway?
The UL 9540A assessment of a 40 MWh system measured 18.4 litres of flammable gas per cell, including HF, CO and H₂. This led to minimum distances and deflagration venting.
Thermal propagation evaluation to UL 9540A → · How thermal runaway unfolds →
Is the claim settled at actual cash value or replacement value?
The policy decides. Actual cash value is the replacement value of an equivalent system less a deduction for age, wear and condition.
Actual cash value of a PV system after a loss →
Frequently asked questions — insurers
How quickly are you on site after a loss?
We respond to enquiries within 24 hours and prioritise losses where evidence needs to be preserved. Offices in Munich and Frankfurt, ready to deploy across Europe.
Can you prove hidden damage, for example after hail?
Yes. Micro-cracks in solar cells are often invisible from the outside; with electroluminescence measurement we make them visible and distinguish hail damage from transport or installation damage. This allows the indemnifiable loss to be delineated cleanly.
What do you provide for battery storage damage?
Cause analysis for thermal runaway, BMS faults and cell defects including chain of causation and loss amount. Plus AwSV review and assessment of consequential damage, from home storage to container-scale systems.
What happens with a total loss?
We determine the residual value of usable components, including the second-life potential of the modules in battery systems. This reduces the settlement amount and creates a sound basis for crediting the residual value.
Do you distinguish serial faults from individual defects?
Yes, and this is often decisive for settlement. Through sample measurements, fault patterns and where necessary laboratory analysis we determine whether there is a product fault, an installation fault or an insured event.